Kits & Panels

ReadiLink™ Rapid mFluor™ Red 780 Antibody Labeling Kit *Microscale Optimized for Labeling 50 µg Antibody Per Reaction*

NEW
ReadiLink™ Rapid mFluor™ Red 780 Antibody Labeling Kit *Microscale Optimized for Labeling 50 µg Antibody Per Reaction*

Article No

ABD-1131

Application

Labeling, FC

Size

2 Labelings

Shipping Information

RT

Product insert

Specifications

Application Labeling, FC
Article No ABD-1131
Country Availability SE, FI, DK, NO, IS, EE, LV, LT, RU
Conjugation mFluor Yellow 780
Description ReadiLink™ Rapid mFluor™ Red 780 Antibody Labeling Kit *Microscale Optimized for Labeling 50 µg Antibody Per Reaction*
Supplier AAT Bioquest Inc.
Notes mFluor™ dyes are developed for flow cytometry-focused applications. These dyes have large Stokes Shifts, and can be well excited by the laser lines of flow cytometers (e.g., 405 nm, 488 nm and 633 nm). mFluor™ Red 780 dyes have fluorescence excitation and emission maxima of ~629 nm and ~780 nm respectively. Like Alexa Fluor 750-APC tandem, it has strong absorption at 633 nm, making its conjugates readily excitable by 633 nm red laser. These spectral characteristics make mFluor™ Red 780 an excellent alternative to Alexa Fluor 700-APC tandem. mFluor™ Red 780 is a small organic molecule that is much easier to use than the Alexa Fluor 750-APC tandem. mFluor™ Red 780 SE is reasonably stable and shows good reactivity and selectivity with protein amino groups. This kit has all the essential components to perform two separate labeling reactions and purifications. Each of the two vials of mFluor™ Red 780 provided in the kit is optimized for labeling ~50 µg antibody. mFluor™ Red 780 antibody labeling kit provides a convenient method to label small amounts of monoclonal, polyclonal antibodies or other proteins (>10 kDa) with the mFluor™ Red 780 dye.
Alias Names Antibody conjugation kit, fluorescent 780
Product Type Kits & Panels
Shipping Information RT
Size 2 Labelings
Stability 6 months
Storage f/l
Technical Specifications AAT Bioquest's mFluor dyes are developed for flow cytometry-focused applications. These dyes have large Stokes Shifts, and can be well excited by the laser lines of flow cytometers (e.g., 405 nm, 488 nm and 633 nm). mFluor Red 780 dyes have fluorescence excitation and emission maxima of ~629 nm and ~780 nm respectively. Like Alexa Fluor 750-APC tandem, it has strong absorption at 633 nm, making its conjugates readily excitable by 633 nm red laser. These spectral characteristics make mFluor Red 780 an excellent alternative to Alexa Fluor 700-APC tandem. mFluor Red 780 is a small organic molecule that is much easier to use than the Alexa Fluor 750-APC tandem. mFluor Red 780 SE is reasonably stable and shows good reactivity and selectivity with protein amino groups. This kit has all the essential components to perform two separate labeling reactions and purifications. Each of the two vials of mFluor Red 780 provided in the kit is optimized for labeling ~50 µg antibody. mFluor Red 780 antibody labeling kit provides a convenient method to label small amounts of monoclonal, polyclonal antibodies or other proteins (>10 kDa) with the mFluor Red 780 dye.
Product Page Updated 2020-06-09T06:59:01.578Z

Shipping info

The delivery time for this item is approximately 5-8 business days. 
If other deviations occur, this will be noted on the order confirmation or communicated via email.
Please note, we do reserve the right to select the best packaging and shipping method in order to insure the stability of the product and allow efficient order tracking.